Dimplex OPTIMYST RTOPSTV20 사용자 설명서 - 페이지 11

{카테고리_이름} Dimplex OPTIMYST RTOPSTV20에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dimplex OPTIMYST RTOPSTV20 12 페이지. Optimyst stove

Dimplex OPTIMYST RTOPSTV20 사용자 설명서
PATENT / PATENT APPLICATION
Products within the Optimyst range are protected by one or more of the following patents and patent applications:
Great Britain GB 2402206, GB 2460259, GB 2460453 , GB 2418014, GB 2465738, GB 2449925, GB 2465537 , GB
2455277 , GB1020534.2, GB1020537.5, GB1110987.3
United States US 7967690, US 2010299980, US 2011062250, US 2008028648, US 13/167,042
Russia RU2008140317
European EP 2029941, EP 2201301, EP 2315976, EP 1787063, EP07723217.1 , EP11170434.2, EP 11170435.9
China CN 101883953, CN 200980128666.2, CN 101057105, CN 101438104
Australia AU 2009248743, AU 2007224634
Canada CA 2725214, CA 2579444, CA 2645939
International Patent Application WO 2006027272
South Africa ZA 200808702
Mexico MX 2008011712
Korea KR 20080113235
Japan JP 2009529649
Brazil BR P10708894-9
India IN 4122/KOLNP/2008
New Zealand NZ 571900

Troubleshooting

Symptom
The fl ame eff ect will
not start.
The fl ame eff ect is too
low.
Unpleasant smell when
unit is used.
The fl ame eff ect has
too much smoke.
Main lamps are not
working and there are
no fl ames or smoke.
Cause
Mains plug is not plugged in.
Low water level.
Low voltage connector not connected properly.
(See Fig.5)
The Transducer Unit is not sitting correctly in
the sump
Flame eff ect control knob is set too low.
(See Fig.10)
The Metal Disc in the transducer might be dirty
(See Fig.14)
The wire from the Transducer Unit is sitting over
the metal disc
Dirty or stale water.
Using unfi ltered tap water.
Flame eff ect setting is too high.
There is no water in the water tank
Corrective Action
Check plug is connected to wall socket correctly.
Check that the water tank is full and there is
water in the sump.
Check that the connector is inserted correctly.
(See Fig.5)
Ensure the Transducer in sitting down into the
moulded recess in the sump
Increase level of fl ame by turning Control knob
'D' to the left slowly. (See Fig.10)
Clean the Metal Disc with soft brush supplied.
(See Fig.14) See 'Maintenance. ' for a step by step
procedure.
Direct the wire to the back of the sump and
make sure it sits into the side slot exiting the
sump.
Clean the unit as described under maintenance.
Use only fi ltered tap water.
Turn the fl ame eff ect Control knob D to the
right, about ¼ a turn, at a time. Give the fl ame
generator some time to adjust to the new
setting. (See Fig.10)
Follow instructions under
Maintenance, 'Filling the water tank' .
Check the plug is connected to the wall socket
correctly and that Switch 'A' Fig. 10 is in the
'ON' ( I ) position.