Aeon Labs ZW175 빠른 시작 매뉴얼 - 페이지 7
{카테고리_이름} Aeon Labs ZW175에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aeon Labs ZW175 9 페이지.
Setting
0 - 2147483647
Parameter 91: Threshold Power (W) for inducing automatic report.
Threshold Power (W) for inducing automatic report.
Size: 2 Byte, Default Value: 0
Setting
0
1 - 2300
Parameter 92: Threshold Power Consumption (kWh) for inducing automatic report.
Threshold Power Consumption (kWh) for inducing automatic report.
Size: 2 Byte, Default Value: 0
Setting
0
1 - 10000
Parameter 93: Threshold Current (A) for inducing automatic report.
Threshold Current (A) for inducing automatic report.
Size: 1 Byte, Default Value: 0
Setting
0
1 - 100
Parameter 101: Configure which meter reading will be periodically report via Lifeline.
The format of the parameter is Bit field (Checkboxes). The parameter MUST be treated as a bit field where each
individual bit can be set or reset. A graphical configuration tool SHOULD present this parameter as a series of
checkboxes.Note:The sending frequency is related to Configuration Parameter 0x6F (111).
Size: 4 Byte, Default Value: 15
Setting
1
2
4
8
Parameter 111: Configure the sending frequency of Meter Report.
Configure the sending frequency of Meter Report.
Size: 4 Byte, Default Value: 600
Setting
0
600 - 2592000
Parameter 255: Factory Reset or Initialization (Write Only)
Factory Reset or Initialization (Write Only)
Size: 1 Byte, Default Value: 0
Description
Value1=Enable Hour, Value2=Enable Minute, Value3=Disable Hour, Value4=Disabale Minute
Description
Disable
1-2300W
Description
Disable
1-10000kWh
Description
Disable
0.1-10A. Unit is 0.1A.
Description
Power Consumption
Power
Voltage
Current
Description
Disable
600-2592000s. (10minute-30day)