Aeon Labs Aeotec Water Sensor 6 매뉴얼 - 페이지 6

{카테고리_이름} Aeon Labs Aeotec Water Sensor 6에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aeon Labs Aeotec Water Sensor 6 12 페이지. Z-wave water sensor

1, This procedure should only be used when the primary controller is inoperable.
2, Reset Water Sensor to factory default settings, it will:
a ), let the Water Sensor to be excluded in Z-Wave network;
b), delete the Association settings;
c), restore the Configuration settings to the default.
5. Special rule of each command
5.1 Basic Command Class
When the water sensor is triggered, it will send the Basic Set 0x00/0xFF (configured by parameter 0x58 and
0x59) to the associated nodes in association group 3 or 4.
Basic Report = 0x00, Water Leak Cleared.
Basic Report = 0xFF, Water Leak Detected
5.2 Z-Wave Plus Info Report Command Class
Parameter
Z-Wave Plus Version
Role Type
Node Type
Installer Icon Type
User Icon Type
5.3 Manufacturer Specific Report
Parameter
Manufacturer ID 1
Manufacturer ID 2
Product Type ID 1
Product Type ID 2
Product ID 1
Product ID 2
5.4 Association Command Class
Water Sensor 6 supports 4 association groups and can add max 5 nodes for every group.
Association
Nodes Send
Group
Group 1
[1,5]
(Lifeline)
Value
1
6 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY)
0x0C07 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY)
Value
AEON LABS=0x00
AEON LABS=0x86
EU=0x00, US=0x01, AU=0x02 CN=0x1D (29)
0x02
0x00
0x7A (122)
Send commands
Mode
Single Cast
1.
Send Battery Report or Multilevel Sensor Report (configured
by parameter 0x65 and 0x6F).
2.
Send Notification Report when water leak is detected.
Note:
group, the Water Sensor will send the "Water leak detected"
notification if any of the probes detect water and "event
cleared" notification if none of the probe longer detects a
When having a classic Node ID association on this
Page 6