FLOOR WALLS & CEILINGS
The minimum mounting heights are: -
1.
Vector I and Vector RP 1.8M
2.
Vector II
3.
Vector III
(Also applies to apposite wall when wall mounted)
The above dimensions also apply to the distance
required to a side wall when suspended and a
distance of 1.0M is required to any end wall for
all heaters regardless of type of mounting.
Allow a minimum space above heaters of 150mm
to any overhang or ceiling. Do not locate heater
immediately below any socket outlet.
VECTOR 1
a. Wall mounting – screw back box to wall using
2 holes (see fig.2).
b. Bracket mounting – fit bracket to wall and back
Box to bracket (see fig.5).
c. Suspended mounting – remove 2 knockouts
(see fig.2) and suspend back box using conduit
or chain hooks.
VECTOR RP
a.
Bracket mounting only – fit bracket to wall and
back box (cover support fitted) to wall bracket
(see fig.5).
VECTOR II & III
a. Wall mounting – screw back box to wall using the 2
or 3 holes provided.
b. Suspended mounting – suspend back box using
conduit or chain hooks.
Fit front assemblies to heater (see fig.7) and adjust
reflector angle to suit and on Vector RP, re-fit rainproof
heater.
INSTALLATION
2.5M
3.0M