Value
1
Get the number of alarm music. (Default)
Alarm Mode When Opening (Parameter Number 37, Parameter Size 4) Configure the alarm
mode for when the garage door is opening. Value1: configure the frequency of blinking for
the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and
the max frequency is level 10. Default is level 10. Value2: configure the alarm sound (there
are 4 types sound saved in EEPROM and user also can update it). Default is type 1. Value3:
configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the
max volume is 10 levels). Default is set to 8. Value4=0, disable the alarm prompt. Value4=1,
enable the alarm prompt.
Value
Configure the flash frequency of the alarm LED, there are 10 levels can be
1 — 10
set.
Select an alarm sound, there are 4 alarm sounds in the flash memory card can
256 — 356
be selected.
65535 —
Configure the volume of alarm sound, there are 10 levels can be set.
65545
16777215
Disable the alarm mode.
16777216
Enable the alarm mode.
Alarm Mode When Closing (Parameter Number 38, Parameter Size 4) Configure the alarm
mode when the garage door is closing. Value1: configure the frequency of blinking for the
Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the
max frequency is level 10. Default is level 6. Value2: configure the alarm sound (there are 4
types sound saved in EEPROM and user also can update it). Default is type 2. Value3:
configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the
max volume is 10 levels). Default is set to 8. Value4=0, disable the alarm prompt. Value4=1,
enable the alarm prompt.
Value
Configure the flash frequency of the alarm LED, there are 10 levels can be
1 — 10
set. (Default 6)
Select an alarm sound, there are 4 alarm sounds in the flash memory card can
256 — 356
be selected.
65535 —
Configure the volume of alarm sound, there are 10 levels can be set.
65545
16777215
Disable the alarm mode.
16777216
Enable the alarm mode.
Alarm Mode Unknown Position (Parameter Number 39, Parameter Size 4) Configuration
alarm mode when the garage door is in "Unknown" state: Value1: configure the frequency of
blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is
level 1 and the max frequency is level 10. Default is level 4. Value2: configure the alarm
sound (there are 4 types sound saved in EEPROM and user also can update it). Default is type
3. Value3: configure the volume of alarm sound (there are 10 levels, the min volume is 1 level
and the max volume is 10 levels). Default is set to 8. Value4=0, disable the alarm prompt.
Value4=1, enable the alarm prompt.
Value
Description
Description
Description
Description