2. Remove the mounting bracket and mark
off the screw positions on the wall or
ceiling.
Fix the bracket in position by
making the necessary wall fixings as
described under the heading "Special
Instructions on Fitting Heater to a Wall or
Ceiling".
3. Locate the heater on the mounting
bracket
ensuring
that
the
hexagonal
headed screws are fully engaged in the
slots of the bracket.
3a. It is important that the serrated metal
washer is located between the heater wall
fixing member and the wall-mounting
bracket.
Adjust heater to the required
angle then firmly tighten the hexagonal
headed screws using the 8mm spanner.
4. Connection to the fixed wiring of the
premises should be done through an
adjacent 20 amp double-pole switch.
5. Connection from the remote control
switch (accessory Ref. No. AC0001) may
be carried out either by conduit entry or
cables run into the heater through a conduit
bush. Refer to circuit diagrams 1 and 2
opposite for removal and substitution of
wires within the appliance.
6. Release the screws securing the mains
supply terminal bracket to gain better
access to the terminal for connection of the
supply cable, which should be carried out
at this point.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
Also ensure that supply cables are of
adequate current carrying capacity and are
protected by a suitable fuse.
If the appliance is mounted in a bathroom,
the appliance should be mounted such that
no part of it can be touched by a person
using a fixed bath or shower. An isolating
switch must be provided outside the
entrance door to the bathroom or be of the
pull-cord type.
7. Re-secure mains supply terminal
bracket,
ensuring that the original screws are used
to do this.
8. Re-secure front cover.