Dimplex GDC18RWA 유지 관리 안내 - 페이지 2

{카테고리_이름} Dimplex GDC18RWA에 대한 유지 관리 안내을 온라인으로 검색하거나 PDF를 다운로드하세요. Dimplex GDC18RWA 11 페이지. Inverter portable air conditioner
Dimplex GDC18RWA에 대해서도 마찬가지입니다: 사용 설명서 지침 (9 페이지), 유지 관리 안내 (13 페이지)

Dimplex GDC18RWA 유지 관리 안내
Dimplex inverter portable air conditioner trouble shooting and maintenance Guidance.
problem
cause
◆电源线插头与插座接
触不良
Incompatiblity
happened at connection
of power plug & its
power socket
◆滤波器烧坏
wave filter being
damaged
一、上电无反应
No signaling-
Electrical live
parts
◆主板20A保险丝烧坏
mainboard fuse of input
current 20A was
damaged
◆CN52或CN57配线端
子松脱
CN52 or CN57 with
loose wiring connection
◆主板烧坏
mainboard damaged
◆压缩机过热保护未解
overheat protection of
compressor fail to
funtion
◆5P通信配线端子松
maintenance
maintenance methods
tool
★更换接触良好的插座
Replace with workable
power plug accordingly
★机器上电开机,使用万用
表在滤波器OUT端测试棕
/蓝端子电压是否有
AC220-240V电压输出?如
有烧坏主更换之。
turn on the unit.to use
multimeter to detect
wave filter "out- signal" to
verfify the voltage wether
at 220-240V.or otherwise
万用表 十字螺丝
to replace it
刀 尖嘴钳
★目测主板保险丝是否烧
断,如有烧断即更换之。
To detect the fuse wether
workable or not
otherwise to replace it
★目测主板CN52\57是否
松脱,如是请用钳子把端子
夹紧重插。
To detect the wiring
connection and affirm It
by using pincer
★目测主板电子元件是否
有明显熏黑、漏电短路爆
裂现象,如是请更换主板
To check any sportmarks
on mainboard chips & its
workability not having
short circuit otherwise to
replace the new one
★用温度计测试排气管湿
度是否高于125℃,如是
证明其热保护开启,待冷
却后再上电运行。
thermometer to check
tempreture at 125℃,If
detect to be overheat but
only to plug on after it is
cool down
★目测主板CN801插座&
驱动板CN7插座配线端是
否松脱,如是请重新插好
再上电。
important notes
※1.断电后半分钟以上,
方可拆机检查。以免电
击伤人和烧毁万用表。
※2.维修人员需接上可靠
的接地,以免静电损坏
主板元件。
※3.主板更换时,请先记
录各配线配插位置,再
实施拆卸,以免安装新
板时配错线上电损坏主
板。
1.please wait at
leat 30 seconds before
discharging unit for
checking.This is to
ensure not harming user
& multimeter.
2.qualified technician to
ensure the live parts to
be earthly grounded in
order to protect the parts
to be safely operated
3.Please record all the
socket lot and wiring
connection before
replacing the new
mainboard.This is to
ensure correct wiring
connection to protect the
live parts
※1.断电后半分钟以上,
方可拆机检查。以免电
击伤人和烧毁万用表
※2.维修人员需接上可靠
的接地,以免静电损坏
第1页/共6页