Dimplex RLG25FC 서비스 매뉴얼 - 페이지 12
{카테고리_이름} Dimplex RLG25FC에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dimplex RLG25FC 18 페이지. 25" electric log set
Dimplex RLG25FC에 대해서도 마찬가지입니다: 소유자 매뉴얼 (14 페이지)
![Dimplex RLG25FC 서비스 매뉴얼](/uploads/products/server2/658690/658690.png)
Back Log Replacement
Tools Required: Philips head screwdriver
WARNING: If the log grate was operating prior to ser-
vicing, allow at least 10 minutes for the heating elements to
cool off to avoid accidental burning of skin.
WARNING: Disconnect power before attempting any
maintenance to reduce the risk of electric shock or damage
to persons.
1. Lift the flame panel from the unit and put it aside in a
safe place.
2. Remove the ember mat by disconnecting it from the
right side of the unit (if applicable).
3. Remove the two screws at the front of the back log.
(Figure 3)
4. Install the replacement log and secure with the two
screws that were previously removed.
5. Reinstall the flame panel.
6. Re-assemble the remainder of the log grate in reverse
order from the instructions above.
WARNING: Ensure wires do not come in contact with
moving parts by securing wires in wiring tie wraps.
Figure 3
Figure 4
Bottom Assembly
12
Figure 5
Blower
Assembly
Log Set Replacement
Tools Required: Philips head screwdriver
WARNING: If the log grate was operating prior to ser-
vicing, allow at least 10 minutes for the heating elements to
cool off to avoid accidental burning of skin.
WARNING: Disconnect power before attempting any
maintenance to reduce the risk of electric shock or damage
to persons.
1. Lift the flame panel from the unit and put it aside in a
safe place.
2. Remove the ember mat by disconnecting it from the
Back Log
right side of the unit.
3. Remove the 3 screws along the bottom of the front and
back of the bottom assembly and the four screws from
each corner on both ends. (Figure 4)
4. Gently tilt the unit onto the back and lower the bottom
assembly so that the electrcial can be easily accessed.
5. Remove the two screws in the bottom of the second
and fourth prongs of the grate to release the logs.
6. Trace the wire from the logs to the main control board
and disconnect the wire, noting the location on the
board.
7. Run the wire from the new logs, following the same
path as the wire that was removed. Attach the new wire
to the board.
8. Install the replacement logs and secure with the two
screws that were previously removed.
9. Re-assemble the remainder of the log grate in reverse
order from the instructions above.
WARNING: Ensure wires do not come in contact with
moving parts by securing wires in wiring tie wraps.
Power Supply
Main Control
Board
www.dimplex.com