Pioneer CX-3195 서비스 매뉴얼 - 페이지 17
{카테고리_이름} Pioneer CX-3195에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Pioneer CX-3195 27 페이지. Cd mechanism module
5
1.4 POWER SUPPLY AND LOADING BLOCK
For the power supply for this system, the VD (7.5 ± 0.5 V) and the VDD (3.3 ± 0.165 V), which are supplied from the
motherboard, are used. The two power supplies, the VD mentioned above (for the drive system), and the VDD (for the LSI:
3.3 V), are used in this system.
The CPU of the LSI controls ON/OFF with "CONT", except for Load/Eject of the CD driver. For ON/OFF of the Loading
drive, no particular control terminals are available, but the input signal "LOEJ" assumes an equivalent role. Also, the LCO
output switches LOADING MODE and CARRIAGE MODE with "CLCONT".
CN901
PGND
15
29
10
19
VD
1
28
2
10
GND
14
VDD
9
Fig.1.4.1 Power supply/loading system circuit block
CLCONT
Fig.1.4.2 Loading/carriage mode shift
5
6
LCOP
18
LOADING
IC301
M
MOTOR
BA5839FP
LCOM
17
9
22
21
Loading Mode
6
7
CLCONT
43 5
3.3VDD
S903 S905 S904
Carriage Mode
Loading Mode
CX-3195
7
8
41
IC201
PE5547A
6
7
8
9
S901
8
A
B
C
D
E
F
17