Pioneer CT-F10 서비스 매뉴얼 - 페이지 23
{카테고리_이름} Pioneer CT-F10에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Pioneer CT-F10 28 페이지. Stereo cassette deck
Pioneer CT-F10에 대해서도 마찬가지입니다: 사용 설명서 (40 페이지), 서비스 매뉴얼 (28 페이지), 추가 운영 지침 (21 페이지)
QQ
3 7 63 1515 0
6.2.1 Playback Section
(1) Tape Speed Confirmation
No.
Mode
Input Signal/Test Tape
1
PLAY
(2) Head Azimuth Confirmation
• This unit is equipped with auto tape selector.
• Do not switch between forward and reverse operation with the screwdriver inserted.
No.
Mode
Input Signal/Test Tape
1
PLAY
(3) Playback Level Adjustment
• Since this adjustment determines playback DolbyNR level, Perform it carefully.
No.
Mode
Input Signal/Test Tape
1
PLAY
(Playback: 315 Hz, 0 dB)
(4) Playback Frequency Characteristics Confirmation
No.
Mode
Input Signal/Test Tape
TE
L 13942296513
1
PLAY
6.2.2 Recording Section
(1) Recording Bias Adjustment
• After the adjustment, caution should be exercised so as not to become under bias by checking the distortion rate.
No.
Mode
Input a 315Hz (-26dBv)signal to
*
1
the REC IN terminal .
(W147:REC L) (W151: REC R)
Load the STD–633 test tape and
REC =
2
record/playback the 315Hz and
PLAY
10kHz signals. (see the Note below)
Note: Set the 10kHz input signal level to the same value as the 315Hz input signal level of step 1.
(2) Recording Level Adjustment
No.
Mode
Input a 315Hz (-10dBv)signal to
1
the REC IN terminal .
*
www
(W147:REC L) (W151: REC R)
• STD–633 test tape and record/
REC =
2
playback the 315Hz signal.
PLAY
.
• DOLBY NR : OFF
*
: In case of adjustment as a single unit, enter the signal at W147(RECL)and W151(RECR) ofMAIN ASSY. At this time, connect an output
buffer amplifier to the oscillator, and then connect a series resistor (180 Ω) after the impedance has become sufficiently low. (For MPX
filter impedance matching)
http://www.xiaoyu163.com
Adjustment Points
NCT-111 (3 kHz)
No Adjustment
Adjustment Points
NCT-132X
Head azimuth
(10 kHz, –20dB)
No adjustment
Adjustment Points
L ch
NCT-132X test tape
R ch
Adjustment Points
NCT-132X test tape
Input Signal/Test Tape
R ch
Input Signal/Test Tape
x
ao
y
i
R ch
http://www.xiaoyu163.com
8
Measurement Points
PB OUT
(PBR:W149)
(MAIN ASSY)
Measurement
Points
PB L cH(W150)
PB R cH(W149)
(MAIN ASSY)
Measurement
Points
VR2301
PB L cH(W150)
PB R cH(W149)
(MAIN ASSY)
VR2302
Measurement
Q Q
3
6 7
1 3
Points
PB L cH(W150)
PB R cH(W149)
(MAIN ASSY)
Measurement
Adjustment Points
Points
PB L cH(W150)
Input signal level
PB R cH(W149)
(MAIN ASSY)
FWD.VR2821
REV.VR2823
L ch
REV.VR2824
FWD.VR2822
Measurement
Adjustment Points
Points
Input signal level
PB L cH(W150)
PB R cH(W149)
u163
VR2401
L ch
(MAIN ASSY)
VR2402
.
2 9
9 4
2 8
Adjustment Value
REV Confirmation
3000 Hz+90Hz
( 3000 Hz + 90Hz )
- 60Hz
FWD / REV
Confirmation
Adjustment
Value
FWD Adjstment
REV Confirmation
–6.0 dBV
( – 6.0 dBv ± 2.0dB )
Adjustment
1 5
0 5
8
2 9
9 4
Value
Check that the frequency
characteristics is within the
range of Fig. 6-2.
Adjustment
Value
–26 dBV
Repeat adjustment until playback level of
the 10kHz signal is within -0.5dB ± 0.5dB
from that of the 315Hz signal.
Adjustment
Value
–10 dBV
m
co
Repeat recording, playback and
adjustment until playback level of the
315Hz signal becomes –10dBV ± 0.5dB.
CT-F10
9 9
Remarks
– 60Hz
Remarks
Remarks
Remarks
2 8
9 9
Remarks
Remarks
23