Pioneer PD-S507 서비스 매뉴얼 - 페이지 2
{카테고리_이름} Pioneer PD-S507에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Pioneer PD-S507 39 페이지.
Pioneer PD-S507에 대해서도 마찬가지입니다: 서비스 매뉴얼 (9 페이지)
- 1. Table of Contents
- 2. Safety Information
- 3. Exploded Views and Parts List
- 4. Front Panel Section
- 5. Schematic Diagram
- 6. Pcb Connection Diagram
- 7. Pcb Parts List
- 8. Main Board Assy
- 9. Adjustment
- 10. General Information
- 10. Display
- 10. Block Diagram
- 11. Panel Facilities and Specifications
- 12. Specifications
PD-S507
1. SAFETY INFORMATION
This service manual is intended for qualified service technicians; it is not meant for the casual
do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been
trained to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may
void the warranty. If you are not qualified to perform the repair of this product properly and safely, you
should not risk trying to do so and refer the repair to a qualified service technician.
IMPORTANT
THIS PIONEER APPARATUS CONTAINS
LASER OF CLASS 1.
SERVICING OPERATION OF THE APPARATUS
S H O U L D B E D O N E B Y A S P E C I A L L Y
INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS
MAXIMUM OUTPUT POWER: 5 mw
WAVELENGTH: 780 – 785 nm
LABEL CHECK
MVXK type
MYXK type
2
MYXK type
REAR
Additional Laser Caution
1. Laser Interlock Mechanism
The position of the switch (S601) for detecting loading
state is detected by the system microprocessor, and the
design prevents laser diode oscillation when the switch
(S601) is not on CLMP terminal side (CLMP signal is OFF
or high level.). Thus, the interlock will no longer function if
the switch (S601) is deliberately set to CLMP terminal
side (low level).
The interlock also does not function in the test mode
Laser diode oscillation will continue, if pin 33 of
CXA1782CQ (IC151) on the MAIN BOARD ASSY is
connected to GND, or pin 22 of IC301(LDON) is
connected to low level (ON), or else the terminals of Q151
are shorted to each other (fault condition).
2. When the cover is opened with the servo mechanism
block removed and turned over, close viewing of the
objective lens with the naked eye will cause exposure to a
Class 1 laser beam.
∗
Refer to page 28.
∗
.