Ariston 110 L 기술 매뉴얼 - 페이지 22
{카테고리_이름} Ariston 110 L에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston 110 L 39 페이지. Heat pump water heater split
BOOST mode
This mode is available by default.
The BOOST is a temporary mode that shall be set by the user when he has an urgent need of hot
water.
By activating this mode, the water heater simultaneously uses the heat pump and heating element
to reach the desired temperature in the shortest possible time. Once this temperature is reached,
the operating mode will automatically go to AUTO mode (with previous settings).
Useful parameters:
Parameter
The desired temperature for the hot water can be set by turning the knob clockwise or
T
set-point
anti-clockwise.
T
Installer menu parameter P1 - Adjustment of the maximum obtainable temperature.
max
T
Installer menu parameter P2 - Adjustment of the minimum obtainable temperature.
min
Installer menu parameter P3 - Adjustment of the maximum temperature obtainable
T
HP
with the heat pump unit.
The temperature of the water in the tank, to visualize press and release the knob; the
T
water
relative value will appear for 8 seconds then the set temperature will reappear.
Legend:
HP: Heat pump
HE: Electrical resistance (1200 W)
≤
Case 1: T
T
set-point
HP
Description/Functioning
22
Default
Range
value
T
÷ T
55 °C
min
max
65 °C ÷ 75 °C
65 °C
40 °C ÷ 50 °C
50 °C
50 °C ÷ 62 °C
55 °C
-
-