O
RDER CODE
ULM – 53
A
CCESSORIES
standard – included in the price
1x Seal (only for ULM–53_–02, 06)
1x Connector socket with the IP67
protection class
S
,
AFETY
PROTECTION
The level meter ULM–53 is equipped with protection against reverse polarity and output current
overload.
Protection against dangerous contact is secured by low safety voltage that complies with
EN 33 2000-4-41.
Electromagnetic compatibility according to EN 55022/B, EN 61326/Z1 and EN 61000-4-2 to 6.
Explosion proof of ULM–53Xi type complies with the following standards: EN 60079-0 : 2007;
EN 60079-11 : 2007 ; EN 60079-26 : 2007 and examined by FTZÚ-AO 210 Ostrava - Radvanice
certifi cate No.: FTZÚ 09 ATEX 0119X.
U
,
SE
MANIPULATION AND MAINTENANCE
The level meter does not require any personnel for its operation. Follow-up displaying device is
used to inform the technological entity operating personnel on the measured substance level
height during the operation.
Maintenance of this equipment consists in verifi cation of integrity of the level meter and of the
supply cable. Depending on the character of the substance measured, we recommend to verify at
least once per year the clarity of the ultrasound transducer emitting fi eld and to clean it, respec-
tively. In case any visible defects are discovered, the manufacturer or reseller of this equipment
must be contacted immediately.
It is forbidden to perform any modifi cations or interventions into the ULM–53 level meter without
manufacturer's approval. Potential repairs must be carried out by the manufacturer or by a manu-
facturer authorized service organization only.
Installation, commissioning, operation and maintenance of the ULM–53 level meter has to be car-
ried out in accordance with this instruction manual; the provisions of regulations in force regarding
the installation of electrical equipment have to be adhered to.
11
Output type: I - Current ; U - Voltage (only for performance "N")
Maximum range: 02 - 0.2 ... 2 m
Performance:
,
COMPATIBILITY AND EXPLOSION PROOF
06 - 0.25 ... 6 m
10 - 0.5 ... 10 m
20 - 0.5 ... 20 m
N - Normal - usable in non-explosive areas only
Xi - Explosive proof - suitable for explosive areas
optional – for extra charge
Stainless fi xing nut UM–G1'' (for ULM–53_–02–_)
Stainless fi xing nut UM–G1 ½'' (for ULM–53_–06–_)
ULM–53