Ariston AQUABRAVO ITD 150 설치, 서비스 및 사용 지침 - 페이지 9

{카테고리_이름} Ariston AQUABRAVO ITD 150에 대한 설치, 서비스 및 사용 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston AQUABRAVO ITD 150 36 페이지. Unvented hot water storage cylinders
Ariston AQUABRAVO ITD 150에 대해서도 마찬가지입니다: 설치 및 사용 설명서 지침 (24 페이지)

3.8
c
onnection oF
w
s
Ater
upply
M
For floor standing models:
Ains
On the front of the unit there is a label to identify the connection ports.
Please check this before making any connection to the unit.
For units up to 300 litres it is recommended that all mains cold water supply
pipe work is a minimum of 22mm. For 500 litre models the supply should be
28mm. An isolating valve should be installed between the cold water supply
and the cylinder for servicing. ALL PIPEWORK MUST BE FLUSHED TO
AVOID DAMAGE TO THE CONTROL VALVES.
Please refer to F
Draining taps must be located in acessible postions to permit the draining of
the whole cylinder. The taps must be a minimal size of at least 15mm
nominal size (preferably 22mm), and manufactured in accordance with BS
2879:1980.
When installing the expansion vessel Ariston recommend it be connected
directly to the combination valve (see Figs 3.9 - 3.10).
i
MportAnt
When installing the expansion vessel,
vertically as air can become trapped in the expansion vessel resulting in
noise.
Do not use a flexible hose to connect the expansion vessel. This must be
hard piped in order to avoid vibration.
See below for acceptable installation practices.
. 3.1 - 3.7 for a suggested installation layout.
iGs
n
:-
ote
install the expansion vessel
Do not
9