Electrical Diagrams
Should the Economy 7 system not to be used, a separate 13 amp supply to
each element will be required through a double pole fused isolating switch
having a contact gap of at least 3mm on each pole.The immersion heater
shall be installed with 85°C rubber insulated HOFR-sheathed flexible cable
complying with Table 8 of BS 6141: 1991. Make the connection{s) to the
immersion heater(s) as per Fig. 3.13 and Fig. 3.14. For High Capacity 500
litre models see Fig. 3.15 (page 20).
Single Element
THERMAL
CUT-GLrr
THERMOSTAT
ELEMENT
Fig. 3.13
LI 0
N 0
THERMAL
CUT-OUT
THERMOSTAT
DAY ELEMENT
3kW
240V~
THERMAL
CUT-OUT
THERMOSTAT
N 0
NIGHT ELEMENT
3kW 240V~
ECONOMY?
Fig. 3.14