Ariston FAST EVO ONT B 16 사용자 설명서 - 페이지 21
{카테고리_이름} Ariston FAST EVO ONT B 16에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston FAST EVO ONT B 16 29 페이지. Instantaneous gas water heater
Appliance shut-off conditions
The appliance is protected from malfunctions by means
of internal checks performed by the electronic P.C.B.,
which stops the appliance from operating if necessary.
Switch off the appliance. Shut off the gas valve, remove
the batteries and contact a qualifi ed technician.
The red LED shows the error codes.
OFF
WARNING!!
Never tamper with or decommission the fl ue gas
sensor. This could affect the proper operation of
the appliance.
Poor draught conditions could cause exhaust gas
backfl ow into the installation room.
Hazard of carbon monoxide intoxication.
WARNING!!
Water with a temperature higher than 50°
cause serious burns.
Always verify water temperature before use.
WARNING!!
DO NOT USE THE APPLIANCE WITHOUT
WATER.
Jumper
Led
appliance protection devices
T
a
b
e l
s
u
m
m
r a
s i
n i
g
e
Red
Description
L.E.D.
Fixed
Battery exhausted Replace battery
Single
The appliance
fl ash
does not turn on
Double
No fl ame
fl ash
detected
Three
Gas valve
fl ashes
defective
Four
Overheat
fl ashes
Temperature
Five
probe
fl ashes
defective
Temporary Shut-Off due to defective fl ue gas
discharge
This device causes the applaince to shut down in the
event of an anomaly in the fl ue gas discharge.
The appliance shutdown is temporary.
After 12 minutes, the aplliance begins the ignition
procedure; if normal conditions have been restored, the
appliance operates as normal. If not, it shuts down and
the cycle is repeated.
WARNING
In the event of a malfunction or if repeated intervention
is required:
- switch the appliace off,
- close the gas valve,
- remove the batteries,
- contact the Technical Assistance Service or a qualifi ed
technician in order to repair the fl ue gas discharge
fault once the cause of the malfunction is detected.
Whenever maintenance work is performed on the
device, use original spare parts only and follow the
relative instructions carefully.
r r
r o
Checks to make
1. Check that
the water fl ow
sensor is properly
connected
2. Check/Replace the
battery
1. Check the gas
cock.
2. Check the position
of the detection
electrode
Check if the gas
diaphram is not
obstructed or locked
1. Check for
a possible
obstruction of the
fl ue
2. Check the water
pressure (too low)
1. Check the cable
of the temperature
probe
2. Check the water
pressure (too low)
21