G
Load-bearing Wall, Floated Coat, L-shaped hook

4.2 Pipe Connection

Attach a pressure-release valve (with an arrow pointed to the direction of water flow) to inlet of the
product (i.e. the side where blue cap is). Pressure-release valve must be connected to draft tube
while hot water pipe should be connected to water outlet (the side where red cap is).
Note: Under normal conditions, pressure-releasing safety valve (CODE35006013104) should be
opened regularly to get rid of calcium carbonate deposition and to make sure there's no clog in it.
Pull the handle to horizontal position to open it and if there's water coming out then it is functional,
if there is not, please contact local customer service
4.3 Connection of Y-shaped Nozzle for condensate drainage
When the product is ready, follow the instruction of figure H to use Y-shaped Nozzle to release the
pressure of the pressure-release valve which is attached to the product package. Connect the
condensate pipe as shown in the figure to make sure Y-shaped Nozzle continuously lead the water
down to drainage system. Drainage pipe should be installed to an environment free from frost.