Ariston Marco Polo Gi7S 11L FFI 사용 설명서 - 페이지 5

{카테고리_이름} Ariston Marco Polo Gi7S 11L FFI에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston Marco Polo Gi7S 11L FFI 29 페이지. Ariston marco polo gi7s 11l ffi/ gi7s 16l ffi domestic gas instantaneous water heater

Ariston Marco Polo Gi7S 11L FFI 사용 설명서
Ⅳ. Handle
4.1 Hot-water output
●Press the power button on the control panel to turn the LCD on. The screen flashes to show
42℃ for 3 seconds (Default temperature setting).
●Open the hot-water faucet, the burner inflames automatically and hot water flows out. (For the first
running, open and close the hot-water faucet repeatedly till water heater inflames, to discharge air
residue in the gas pipe.)
●The faucet is recommended to be turned to large extent. Otherwise ignition may be unavailable, or
it may be flameout during the cold-water mixing process.
●The water heater adopts new safe and gas-saving technology. Gas will be cut off automatically after
water heater works for 45±3min without interruption. Then burner is extinguished. If more service is
required, just close the faucet for several seconds and restart, re-ignition will be available then.
7
4.2 Water temperature adjustment
●If both control panel and wireless remote controller are connected with water heater, please confirm if
priority indication lamp is on.
If priority indication on
the control panel turns
bright
If priority indication on
the control panel does
not turn bright
Adjustment by
control panel
If priority indication on
the control panel turns
flashing
If priority indication on
the wireless remote
controller turns bright
If priority indication on
the wireless remote
Adjustment by
controller does not
wireless remote
turn bright
controller
If priority indication on
the wireless remote
controller flashes
●Temperature setting range of water heater is 35-70℃. When temperature is within 35-48℃,tap the
temperature setting button to increase or decrease temperature, it actually switches by 1℃/tap.
Right after the completion of temperature setting, temperature icon flashes for 3 sec and then stays still.
If temperature is within 50-70℃, tap the temperature setting button to increase or decrease the
temperature by 5℃/tap. And when temperature setting completes, temperature icon flashes for 10 sec
and then stays still.
●Control panel is given priority. It's allowed to
start/stop water heater, adjust the water
temperature, set water flux and etc.
●Remote controller is given priority. Therefore
temperature adjustment is not available for the
control panel. User can only read the
temperature, however, on/off button still works.
●Start/stop the water heater with on/off button
to get the priority. Then priority indication turns
bright.
●Remote controller is given priority. Water
temperature adjustment is locked at this time,
because hot water is being used. User can only
read the temperature, however, water flux
setting still works.
●In such case it is impossible for the control
panel to get priority. On/off button is invalid.
●Remote controller is given priority. It's allowed
to start/stop water heater, adjust the water
temperature, set water flux and etc.
●If hot water is not working, tap the priority
button then the priority icon disappears.
Meanwhile control panel is given priority.
●Control panel or other remote controller is
given priority. Adjustment buttons are locked,
user can only read the temperature. And other
function buttons are invalid, too. On/off button
can only start or stop remote controller but not
water heater.
●Tap the priority button to get priority. Start
setting and/or adjustment till priority icon
shows up.
●Control panel or other remote controller (if
more than one remote controllers are mounted)
is given priority. Adjustment buttons are locked
because hot water is working. At this time, user
can only read the temperature. And other
functions are unavailable, too. On/off button
can only start or stop remote controller but not
water heater.
●In such case it is impossible to get priority.
8