Version

Parameter
Z-Wave Protocol Library Type 0x03
Z-Wave Protocol Version
Z-Wave Protocol Sub Version
Firmware 0 Version
Firmware 0 Sub Version
Hardware Version
Number of firmware targets
4.7

Association Group Info

Root product
ID
Name
Node count Profile
1
Lifeline
5
2
control
5
3
Alarm
5
4
Tamper
5
4.8

Notification

Notification Type
Home Security
0x07
0x08
Power Management
Water Alarm
0x05
AEOTEC User Manual
Value
0x07
0x0E
0x02 [Z-Wave Chip Firmware Version]
0x00 [Z-Wave Chip Firmware Sub Version]
0x01
0x00
General: Lifeline
(0x0001)
Notification:
water
alarm
(0x2001)
Notification:water
alarm (0x7105)
Notification:home
Security (0x7107)
Notification Events/State
Tampering, product cover removed
Idle
Replace battery now
Idle
Water leak detected
Idle
Function
Product Reset Locally Notification:
Issued when Factory Reset is performed.
Battery Report:
Issued when battery becomes low.
Sensor Binary Report:
Issued when water leakage state is changed.
Multilevel Sensor Report
Issued when button pressed to wake up or auto report enable or
detect temperature/humidity change exceeds the set value.
Notification Report [Type=0x06; Event=0x16]:
Issued when sensor state is changed to be Open Status.
Notification Report [Type=0x06; Event=0x17]:
Issued when sensor state is changed to be Close Status.
Notification Report [Type=0x07; Event=0x03]:
Issued when tamper is tripped.
Basic Set:
Issured when water leak detected/or not.
Notification Report:
Sends out alarm message when water leakage is detected.
Notification Report:
Sends alarm messages when tamper is tripped.
Description
0x03
Issured when product cover removed
0x00
0x0B
Issued when the battery power lower
than 20%.
0x00
Issured when replace new battery that
battery power more than 90%.
0x02
Issured when water probe detected
water.
0x00
Issured when water probe does not
detect water.