INTEGRAL I
CLOCK '
INTEGRAL BOILER CONNECTIONS
1
2 ZONE
,
CLIP-IN
I
Valve
Valve
I
1
2
I
REMOVE
^ LINK ^
Note:
Enable Parameter 223
and change from 0 to 1
GENUS Range program time
zones 1 & 2 on digital display
CLAS HE both zones timed
from integral timer
240 V
E
N
L
3
4
5
6
7
8
9 10 11 12 13
TERMINAL
BLOCK
/ 4 CALLING
'
ROOM
THERMOSTAT
2« SATISFIED
CALLING
E
GR OR BR BL
E GR OR BR BL
WN MOTORISED
C/H MOTORISED
VALVE (ZONE 1)
VALVE (ZONE 2)
Note: Orange & Grey wires not used
HIGH LIMIT
STAT
CYLINDER
THERMOSTAT*
* Terminals shown are for the Ariston
Unvented Hot Water Cylinder Thermostats