Setting
1
2
4
8
256
512
2048
4096
65536
131072
524288
1048576
Parameter 110: Set parameter 111-113 to default value.
Set parameter 111-113 to default value.
Size: 1 Byte, Default Value: 0
Setting
0
Parameter 111: Set the interval of automatic report for Report group 1.
Set the interval of automatic report for Report group 1.
Size: 4 Byte, Default Value: 10
Setting
1 - 2147483647
Parameter 112: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 2.
Size: 4 Byte, Default Value: 600
Setting
1 - 2147483647
Parameter 113: Set the interval of automatic report for Report group 2.
Set the interval of automatic report for Report group 3.
Size: 4 Byte, Default Value: 600
Setting
1 - 2147483647
Parameter 120: Configure the external switch mode for S1.
Configure the external switch mode for S1.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
Parameter 121: Configure the external switch mode for S2.
Configure the external switch mode for S2.
Size: 1 Byte, Default Value: 0
manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132
manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132
Description
Send Meter Report of voltage (V)
Send Meter Report of current (A)
Send Meter Report of wattage (W)
Send Meter Report of energy (kWh)
Send Multi Channel Meter Report of wattage (W) on Channel 1
Send Multi Channel Meter Report of wattage (W) on Channel 2
Send Multi Channel Meter Report of energy (kWh) on Channel 1
Send Multi Channel Meter Report of energy (kWh) on Channel 2
Send Multi Channel Meter Report of voltage (V) on Channel 1
Send Multi Channel Meter Report of voltage (V) on Channel 2
Send Multi Channel Meter Report of current (A) on Channel 1
Send Multi Channel Meter Report of current (A) on Channel 2
Description
Reset the parameter 111-113
Description
The range of interval time is 1 to 2147483647.
Description
The range of interval time is 1 to 2147483647.
Description
The range of interval time is 1 to 2147483647.
Description
Enter automatic identification mode
2-state switch mode
3 way switch mode
Momentary push button mode
7/10