Aeotec Smart Switch 7 사용자 설명서 - 페이지 7

{카테고리_이름} Aeotec Smart Switch 7에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aeotec Smart Switch 7 8 페이지.
Aeotec Smart Switch 7에 대해서도 마찬가지입니다: 매뉴얼 (18 페이지), 매뉴얼 (6 페이지)

Aeotec Smart Switch 7 사용자 설명서
25.11.2019
Byte value = 0x(Value 1)(Value 2)(Value 3)(Value 4)
Suggestion - use a "hexadecimal to decimal converter" that can be easily found on google.
For example:
If you want to set Night Light Mode to be enabled at 19:00 at night and disable at 07:30 in the morning, you just need to
configure:
Value1=0x13, Value2=0x00, Value3=0x07, Value4=0x1E.
Input 0x1300071E into a hexadecimal calculator, the output decimal value will be 318768926.
Parameter 91 - Watt threshold.
If Watt passes the threshold setting by + or -, a Watt report will be sent to update its value.
Size = 2 Byte
Default Setting = 0
Value
Description
0
Disable Watt threshold.
1 - 2300
Watt threshold setting.
Parameter 92 - kWh threshold.
If kWh passes the threshold setting by + or -, a kWh report will be sent to update its value.
Size = 2 Byte
Default Setting = 0x0064 or 100
Value
Description
0
Disable kWh threshold.
1 - 10000 kWh threshold setting.
Parameter 93 - Current threshold.
If current passes the threshold setting by + or -, a current report will be sent to update its value.
Size = 1 Byte
Default Setting = 0
Value
Description
0
Disable Current threshold.
Current threshold setting
1 - 100
by scale of 0.1A
If value 10 is set, this is the equivalent of setting threshold to 1.0A.
Parameter 101 - Timed report enable/disable.
Sets what sensors should be reported at a timed interval. This can be used at the same time as threshold reporting to allow
both thresholds and timed reports to be used.
Size = 4 Byte
Default Setting = 0 (disabled)
Value
Description
1
kWh (Accumulated Power)
Watt (Power used at the
2
time of the report)
4
Current
8
Voltage
The values in the table above should be added together.
For example:
If you want kWh and Watt only, you would add 1 + 2 = 3.
If you want all values (current, voltage, watt, kWh) reported at an interval, you would add 1 + 2 + 4 + 8 = 15.
https://aeotec.freshdesk.com/support/solutions/articles/6000219911-smart-switch-7-user-guide-
Smart Switch 7 user guide : Aeotec Group
7/8