Ariston BCH 120 L 기술 설치 지침 및 사용자 설명서 - 페이지 28

{카테고리_이름} Ariston BCH 120 L에 대한 기술 설치 지침 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston BCH 120 L 29 페이지. Heating tank

Ariston BCH 120 L 기술 설치 지침 및 사용자 설명서
Technical Installation Instructions and User Guide

Cabling diagram

IMPORTANT: THE ELECTRONIC CIRCUIT MUST ONLY OPERATE AT 230V!
Black
GB
Titanium anode

CARE AND MAINTENANCE

THE CURRENT MUST BE CUT BEFORE ANY OPERATION IS CARRIED OUT ON THE UNIT
All operations must be carried out by a quali ed technician.
We recommend subscribing to a maintenance contract and planning to replace the safety assembly at least every 5 years, if necessary.
Every year (twice a year if the water is treated by a water softener), the unit must be drained so that the Protech anode can be checked to make
sure it is functioning properly.
For these operations, contact your trusted installer.

Exterior cleaning

The external parts of the tank must be cleaned using a damp cloth and appropriate cleaning products that are available commercially. In any
case, the use of abrasive products, solvents, spirits, alcohol, etc. is not recommended.

Draining

Unplug the water heater and the hydraulic supply.
Open the hot water valve to let air in.
Open the drainage valve on the safety assembly.

Remove limescale

In cases of very hard water, it is advisable to remove limescale at least twice a year.
To do this, it is
rst of all necessary to empty the hot water tank and then remove the upper
cess the interior. Carry out the task using a suction device and a plastic or wooden brush (to remove the most
resistant sediment). Clean it again and rinse it with a spray of water.
While cleaning, be careful not to damage the enamel layer that protects the inside of the reservoir.
Replace the upper ange, install a new seal and ll the reservoir, making sure there are no leaks.
28
Red
Electronic circuit
Relays
Connections
ange to be able to ac-