Ariston Contract STI 300 indirect 설치 설명서 지침 - 페이지 15

{카테고리_이름} Ariston Contract STI 300 indirect에 대한 설치 설명서 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston Contract STI 300 indirect 24 페이지. Unvented hot water storage cylinders
Ariston Contract STI 300 indirect에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (20 페이지)

Ariston Contract STI 300 indirect 설치 설명서 지침
W
S
2
IRING
CHEME FOR
1
4
3
5
2
2
T6360B
ROOM
OR
THERMOSTAT
BROWN
5
BLUE
2
GREY
1
ORANGE
10
GREEN/YELLOW
3
V4043H
HEATING VALVE
BROWN
8
BLUE
2
GREY
1
ORANGE
10
GREEN/YELLOW
3
V4043H
HOT WATER VALVE
L
1
N
2
E
3
240V
MAINS INPUT (3 AMP)
Cylinder
thermostat
1
Thermal
P
cut-out
1
P
2
E
L
N
240V
MAINS INPUT (13 AMP)
F
. 2.14
IG
INDIRECT SYSTEMS
For models up to 300 litres a mains supply of 240V, 3kW (13 amps) will be
required for the direct immersion heater. heat resistant cable, round 3 core
2.5mm
2
(to BS) must be used. For High Capacity 500 litre models consult
the wiring diagram on the reverse of the inspection panel.
For indirect controls a 240V, 3 amp supply is required.
On Comfort models the indirect thermostat is factory fitted, for Contract and
High Capacity models it is necessary to fit the thermostat using P.T.F.E tape
(Please consult the label on the face of the unit for the correct location in
both cases).
The cables must be clamped in position (as previously stated) and the
control thermostat should be set at 60°C for the reasons above. In addition
to the thermostat there is a thermal cut-out should the thermostat fail. Refer
to F
. 2.14 and F
IG
2 P
M
V
X
ORT
OTORISED
ALVES
A
1
B
5
CM 41
CM 51
TYPICAL
JUNCTION BOX
• 1
• 2
• 3
• 4
• 5
• 6
• 7
• 8
• 9
• 10
8
1
6
P
Not
2
used
15
. 2.15 for full wiring instructions.
IG
Thermal
Thermostat
cut-out
L1
240V~
N
ELEMENT
3 kW 240V~