1.6
Access to the Control
System
B005
Supplied By www.heating spares.co Tel. 0161 620 6677
Fig. 1.51
Fig. 1.53
A5
A5
Fig. 1.49
Checking fuse
1. Remove the right hand inspection cover (see fig. 1.51) ;
2. Remove fuse (see fig. 1.52) .

Removing the time clock

1. Remove left hand inspection cover (see fig. 1.53) ;
2. Remove electrical connection "A5" of the clock (see fig.
1.54) ;
3. Unscrew "A6" and remove (see fig. 1.55) .
N.B.
It is possible to by-pass the time clock in the event of
failure by simply unplugging the electrical connection from
the P.C.B. (see fig. 1.54 ). This will revert control of the
central heating to the room stat connection on the reverse
of the control panel.
A6
Fig. 1.52
A6
Fig. 1.50
19