Ariston micro GENUS Type C 설치 지침 매뉴얼 - 페이지 16
{카테고리_이름} Ariston micro GENUS Type C에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston micro GENUS Type C 25 페이지. Type c boilers
Ariston micro GENUS Type C에 대해서도 마찬가지입니다: 사용자 설명서 (20 페이지)
3.2
C
P
ONTROL
ANEL
L
:
EGEND
A - On/Off knob
B - Domestic hot water temperature adjustment knob
C - Central heating selection (winter) and temperature
adjustment knob
D - On/Off L.E.D. (green)
E - Fume sensor L.E.D. (yellow)
F - Ignition failure (lockout) L.E.D. (red)
G - "Economy/Comfort" mode selection knob
H - Ignition failure (lockout) and/or overheat reset button
I
- Overheat L.E.D. (red)
J - Low system water level L.E.D. (red)
K - Central heating temperature L.E.D (yellow)
L - Time clock
M - Heating system pressure gauge
3.3
R
EMOVING THE
F
P
RONT
ANEL
1
2
3
A
FO006A
FO012A
FO013A
In order to access the inside of the boiler, it is necessary to unscrew
the fastening screws "A" of the control panel located on the lower part
of the panel itself.
The control panel moves downward and when pulled forward rotates
on two lateral hinges.
The panel stays in a semi-horizontal position, which allows access to
the inner parts of the boiler.
In order to increase the maneuvering space, it is possible to raise the
control panel and rotate it to a fully horizontal position.
4
B
5
16
FO009A
To dismantle the front
casing panel it is necessary
to:
1 - Remove the two screws
"B";
2 - Lift the front casing panel
up and forward.
FO008A
F
. 3.1
IG