In addition, it is also possible to use a split (twin pipe)
system by fitting a special adaptor to the flue connector
and using the aperture for the air vent intake located on
the top part of the combustion chamber.
To utilise the air intake it is necessary to:
1. Remove the bottom of the air intake by cutting it with a
suitable knife (see F
. 2.8);
IG
2. Insert the elbow into the air intake until it reaches the
lower end. (There is no need to use gaskets or sealing
compounds).
The components marked * in F
depending on the type of flue system used by the installer.
F
. 2.9
IG
C
S
OAXIAL
YSTEMS
F
. 2.10
IG
2.9 are present or absent
IG
Ø 80 mm
FU004A
F
. 2.8
IG
FU001A
10
I
!
MPORTANT
For all flue systems, a restrictor
may be be inser ted into the
boilers flue connector; the
restrictor must be Ø 43 in
diameter depending on the length
of piping indicated in T
F
2.10 and F
2.11 illustrate
I G
I G
some of the various designs for
coaxial or twin pipe flue systems.
For
fur ther
infor mation
discharge/ventilation accessories,
see the F
P
A
L U E
I P E
C C E S S O R I E S
M
.
ANUAL
FU005A
FU006A