Ariston microGENUS HE 24 MFFI 사용자 설명서 - 페이지 4
{카테고리_이름} Ariston microGENUS HE 24 MFFI에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston microGENUS HE 24 MFFI 8 페이지. Boiler
* Warning! the flue analysis mode must
only be selected by a qualified service
engineer.
2. OPERATING INSTRUCTIONS
K
4
C
P
ONTROL
ANEL
E
C
L
:
EGEND
A - On/Off Button
B - Domestic Hot Water Temperature Adjustment
C - Central Heating Temperature Adjustment
D - Reset Button/Flue Test analysis mode*
E - Comfort Mode Selector
F - Summer Mode LED (Green)
G - Ignition/Overheat Lockout LED (Red)
H - Central Heating (Winter Mode) LED (Green)
I - Digital Display (Fault Code/Water Temperature)
J - Time Clock
K- Central Heating System Pressure Gauge
Installation, start-up, adjustments and maintenance must be performed by a
competent person only, in accordance with the current Gas Safety (Installation &
Use) Regulations and the instructions provided. Improper installation may cause
damage or injury to individuals, animals and personal property, for which the
manufacturer will not be held liable.
To ensure efficient and safe operation it is recommended that the boiler is serviced
annually by a competent person.
If it is known or suspected that a fault exists on the appliance, it must not be used
until the fault has been corrected by a competent person.
To get the most out of your boiler, we have provided you with some useful advice on
proper use and maintenance:
- Periodically check the system pressure using the pressure gauge "K", make sure that
the pressure is between 1.0 and 1.5 bar (the blue part on the gauge) when the system
is off and cool. The display will indicate "E E 0 0 2 2 " if the pressure is below the minimum
recommended value. Consult your installer for checking and refilling the system.
- The outer panels of the unit's case must only be cleaned with a damp cloth. Do not use
abrasive cleaners. The control panel can be wiped with either a damp or dry cloth.
Spray polishes must not be used on the control panel surface or knobs. Care must be
taken in preventing any liquid entering the appliance.
I
I I
C
AUTION
H
S
ELPFUL
UGGESTIONS
J
K