Ariston microSYSTEM 설치 지침 매뉴얼 - 페이지 10

{카테고리_이름} Ariston microSYSTEM에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston microSYSTEM 24 페이지. Type c boilers

2.10 F
C
LUE
ONNECTIONS
F
. 2.5
IG
Ø 60/100 mm
F
. 2.6
IG
F
S
LUE
YSTEM
The provision for satisfactory flue termination must be made as described in
BS 5440-1, for IE recommendations I.S.813.
The appliance must be installed so that the flue terminal is exposed to
outdoor air, consideration must be given to terminal discharges onto a
pathway or passageway, check that the combustion discharges will not
cause a nuisance and that the terminal will not obstruct the passageway.
The terminal must not discharge into another room or space such as an
outhouse or lean-to.
It is important that the position of the terminal allows a free passage of air
across it at all times.
If the terminal is fitted within 1 metre of a plastic gutter, within 500mm of a
painted eave or a painted gutter, an aluminium shield of at least 1 metre
long should be fitted to the underside of the gutter or painted surface. An air
space of 5mm should be left between shield and gutter.
The terminal should be located with due regard for the damage or
discolouration that might occur on buildings in the vicinity.
In cold or humid weather water vapour may condense on leaving the flue
terminal. The effect of such "steaming" must be considered.
If the terminal is less than 2 metres above a balcony, above ground or above
a flat roof to which people have access, then a suitable terminal guard must
be fitted. When ordering a terminal guard, quote the appliance model
number.
A suitable terminal guard is available from:
TOWER FLUE COMPONENTS
Morley Road
Tonbridge
Kent TN9 1RA
The minimum acceptable spacing from the terminal to obstructions and
ventilation openings are specified in F
T
P
ERMINAL
OSITION
A -
Directly above or below an openable window
or other opening
B -
Below gutters, solid pipes or drain pipes
C -
Below eaves
D -
Below balconies or car-port roof
E -
From vertical drain pipes and soil pipes
F -
From internal or external corners
G -
Above ground or balcony level
H -
From a surface facing a terminal
I -
From a terminal facing a terminal
J -
From an opening in the car port
(e.g. door, window) into dwelling
K -
Vertically from a terminal in the same wall
L -
Horizontally from a terminal in the same wall
M -
Horizontally from an opening window
N -
Fixed by vertical flue terminal
The boiler is designed to be connected to a coaxial flue discharge system.
10
. 2.5.
IG
mm
300
75
200
200
150
300
300
600
1200
1200
1500
300
300