Setting Description
0
Disable
1
Enable
Parameter 6: Group 2 Association Triggers.
This parameter defines events that result in sending On/Off commands to devices added to the 2nd Association Group.
These commands are sent alternately to switch the devices On and Off. Commands represent the values of BASIC
SET command frames. This parameter is inactive in external dry-contact mode (parameter "Operation Mode" set to 1).
Size: 1 Byte, Default Value: 0
Setting Description
0
switch after opening and closing
1
switch after opening
2
switch after closing
Parameter 7: Commands sent to associated devices on Group 2.
Command frames sent to devices added to the 2nd association group.
Size: 1 Byte, Default Value: 2
Setting Description
0
On
1
Off
2
On and Off
Parameter 8: Values of ON command frame sent to Group 2 Association.
The value of 0 turns OFF the device, 255 turns it On. In the case of associating the Dimmer or Roller Shutter module,
values
Size: 1 Byte, Default Value: 255
Setting Description
allow setting an Associated device to a
0 - 99
specified level (0 is OFF)
255
ON
Parameter 9: Value of OFF command frame sent to Group 2 Association.
The value of 0 turns OFF the device, 255 turns it On. In the case of associating the Dimmer or Roller Shutter module,
values.
Size: 1 Byte, Default Value: 0
Setting Description
allow setting an associated device to a
0 - 99
specified level. (0 is OFF)
255
ON
Parameter 10: Time Delay of ON command from Group #2.
The time period after which On command frame will be sent.
Size: 2 Byte, Default Value: 0