communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is
significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox.
Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this
controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the
device. To wakeup the device please perform the following action: Pressing the Action Button once will trigger sending the Wake up notification command. If press
and hold the Z-Wave button for 3 seconds, the Water Sensor will wake up for 10 minutes.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1.
Make sure a device is in factory reset state before including. In doubt exclude before include.
2.
If inclusion still fails, check if both devices use the same frequency.
3.
Remove all dead devices from associations. Otherwise you will see severe delays.
4.
Never use sleeping battery devices without a central controller.
5.
Dont poll FLIRS devices.
6.
Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are
always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
1
2
3
4

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 2: Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 8: Set the timeout of awake after the Wake Up CC is sent out..
Set the timeout of awake after the Wake Up CC is sent out..
Size: 1 Byte, Default Value: 30
Setting
8 - 127
Parameter 9: Report the current power mode and the product state for battery power mode
Report the current power mode and the product state for battery power mode.Note: this parameter cannot be used as Set usage.
Size: 2 Byte, Default Value: 0
Maximum
Description
Nodes
5
Lifeline group.1. The Battery Report or Multilevel Sensor Report (Configurable) can be sent to the
associated nodes in group 1.2. When the water leak is detected, the Notification Report will be
send to the associated nodes in group 1.3. When the Water Sensor is reset, the Device Reset
Locally CC will be send to the associated nodes in group 1.
5
Send the configuration parameter 136 (0x88) to the associated nodes in group 2.
5
Send Basic Set (configured by parameter 88 (0x58) to the associated nodes in Group 3 when the
Sensor probe 1 is triggered.
5
Send Basic Set (configured by parameter 89 (0x59) to the associated nodes in Group 4 when the
Sensor probe 2 is triggered.
Description
Disable
Enable.
Description
Available rang is 8 to 127 seconds.