Installation
Please read these instructions fully.
GB
ENSURE THAT THE OVEN IS INSTALLED BY A
QUALIFIED ELECTRICIAN FOLLOWING THE
INSTRUCTIONS BELOW.
Where to put your oven
1. Your oven should not be located adjacent to a gas
hob/heater or eye level grill as flames from the
burners could cause damage to your oven.
2. For your own safety and to get the best results
from your oven it is important to read through this
Handbook before using your oven for the first time
including the "Always" and "Never".
Electrical Requirements
•
For your own safety, we recommend that your cooker
is installed by a competent person - such as one
who is registered with NICEIC (National Inspection
Council for Electrical Installation Contracting). The
cooker should be installed in accordance with the
latest Edition of the IEE Regulations.
WARNINGS
-
INCORRECT INSTALLATION COULD AFFECT
THE SAFETY OF THE OVEN.
-
THIS APPLIANCE MUST BE EARTHED.
-
BEFORE CONNECTING OR INSTALLING THE
OVEN THE ELECTRICITY SUPPLY MUST BE
SWITCHED OFF.
•
THE INSTALLER MUST check that the voltage
shown on the rating plate corresponds with the
house electricity supply.
•
The oven must be supplied via a suitable double
pole isolating switch, having a contact separation
of at least 3 mm in all poles placed in a readily
accessible position adjacent to the unit.
•
The maximum loading for your oven is 5.3kW.
•
If the oven is to be wired into a connector unit this
may be positioned behind the oven provided the
following requirements are met:
i) The connector unit must not project from the wall
more than 25 mm.
ii) The top of the connector must not be more than
350 mm above the base of the oven recess.
•
After unpacking the oven stand it on the packing
base in order to avoid damage.
2
Electrical connections
•
Remove the terminal cover at the rear base of the
oven. Pass the cable through the cable clamp and
connect to the appropriate terminals provided.
Allow sufficient cable so that the oven can be set
down on the floor whilst still connected up. Tighten
the screws on the cable clamp and replace the
terminal cover. Make mains connections. This
appliance conforms to EN55014 regarding
suppression of Radio and Television reception
interference. Where a double oven is used a 32
amp double pole control switch should be used to
feed the unit using a suitable rated cable. We
recommend that a minimum of 4mm2 PVC insulated
twin and earth cable conforming to B.S. 6004.
•
Where a hob is fitted adjacent to an oven then a 45
amp Double Pole control switch should be used to
feed both units via separate suitably rated cables.
We recommend that a minimum of 4mm2 PVC
insulated twin and earth cable conforming to B.S.
6004.
WARNING: CHILDREN SHOULD NOT BE ALLOWED
TO PLAY WITH THE APPLIANCE OR TAMPER