LP Gas Hook Up
Vent the enclosure for an LP gas cylindar with openings
at the level of the cylinder valve and at the floor level.
Ensure one side of the enclosure is completely open.
For enclosures that have four sides, complete with a
top and bottom:
•
At least two ventilation openings at cylinder valve
less than one square inch per pound (7.1 cm²/kg)
of stored fuel capacity and not less than a total free
area of 10 square inches (64.5cm²). If ventilation
openings at floor level are in a sidewall, there
shall be at least two openings. The bottom of the
openings shall be at floor level and the upper edge
no more than 5 inches (127 mm) above the floor.
The openings shall be equally sized, spaced at
180º (3.14 rad) and unobstructed.
Natural Gas
Warning: All pizza ovens use LP unless they are
converted to natural gas. Do not connect natural gas to
an unconverted pizza oven!
Requirements
Always check the rating plate to make sure the gas
supply you are hooking up to is the gas type the pizza
oven is manufactured for.
IMPORTANT: Never connect the pizza oven to an
unregulated gas supply.
The installation of this appliance must conform with
local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1998. Installation
in Canada must be in accordance with the standard
CAN/CGA-B149.2, Propane Installation Code.
A licensed contractor or local gas company
representative must perform all natural gas
connections.
Ensure that the service supplying the pizza oven is
fitted with a shut off valve conveniently positioned near
the pizza oven and giving ease of access.
The pizza oven and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressure in
excess of 0.5 psi (3.5 kPa).
2007 Pizza Oven Owner's Manual
LTR20071039, Rev. A
Installation / Assembly
•
Every opening shall have minimum dimensions so
as to permit the entrance of a 1/8 inch (3.2 mm)
diameter rod.
Transporting and Storing LP Gas
Place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use. Only install the type
of dust cap on the cylinder valve outlet that is provided
with the cylinder valve. Other types of caps or plugs
may result in leakage of propane.
Transport only one cylinder at a time. Ensure the
cylinder is secured in an upright position with the
control valve turned off and the dust cap in place. Store
cylinders outdoors and out of reach of children. Do
not store cylinders in a building, garage, or any other
enclosed area.
Your pizza oven for use with natural gas comes
equipped with its own regulator that MUST NOT
be removed. If this regulator needs to be replaced,
use only the type specified by Cal Flame™ for this
appliance.
Connection
1.
Remove the rear panel from the pizza oven to gain
access to the regulator and gas connection point.
2.
Connect a suitable flex connector to the regulator.
3.
Check the controls to ensure all control valves are
in the full OFF position.
4.
Turn on the main gas supply and check all
connections for leaks using soapy water as
described in the leak testing procedure section.
Warning: If you see bubbles in the soapy solution at
any of the connections, turn off the gas supply and
tighten the connection. If tightening the connection
does not seal the leak, it may be necessary to replace
the flex hose.