09.08.1999 / Page 2
Doc. No: 4812 712 14571
Technical data
Dimensions
Height
Width
Depth
Weight
Without packing
Main connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Wash spin
Ramp spin
Speed spinning max.
Capacity of dry laundry
Cotton/coloured laundry
Cotton rapid
Easy care
Easy care rapid
Delicate
Wool
Pressostat
Quantity of water washing
Cotton/coloured laundry
Easy care
Delicate
Wool
Overflow
Quantity of water rinse
Cotton/coloured laundry
Easy care
Delicate
Wool
Overflow
Nominal current
Contacts:
11 - 12
11 - 14
11 - 16
Contactsystem:
11-12-14
11 - 16
AWM 312/3
8570 312 53010
85
cm
59.5
cm
55
cm
73
kg
230
V
50
Hz
2.3
kW
10
A
48
l
54
rpm
110
rpm
1200
rpm
5
kg
3
kg
2.5
kg
1.5
kg
1.5
kg
1
kg
9.5
l
9.5
l
14
l
16.5
l
30
l
12
l
11.5
l
15
l
17
l
30
l
4 (4)
A
16 (4)
A
1 (1)
A
jump contacts
slow action contacts
Whirlpool Europe
Customer Service
Door lock
Lock time
Unlock time
Nominal voltage
Nominal current:
contact 4 - 5
contact 11 - 14
Heating element
Kind of heating
Tubular heating element with
NTC-sensor
Nominal voltage
Nominal power
Heat conductor
resistance
Resistance NTC:
0˚C
30˚C
40˚C
50˚C
60˚C
70˚C
95˚C
Inlet valve (cold)
Water temperature max.
Rated flow
< 1 bar
Pressure range
Nominal voltage
Frequency
Starting voltage < 6 bar
6-10 bar
Nominal current
Nominal power
Nominal resistor (20˚C)
Inlet valve (hot)
Water temperature max.
Rated flow
< 1 bar
Pressure range
Nominal voltage
Frequency
Starting voltage < 6 bar
6-10 bar
Nominal current
Nominal power
Nominal resistor (20˚C)
S E R V I C E
3" - 6"
( 20˚C )
60" - 90"
230
V
1
mA
16 (4)
A
230
V
2050
W
Ω
28.09
35.9
kΩ
9.8
kΩ
6.6
kΩ
4.6
kΩ
3.2
kΩ
2.3
kΩ
1.1
kΩ
60
˚C
4
l/min
0.5-10
bar
220-240
V
50
Hz
160
V
170
V
35
mA
6
VA
4060
kΩ
90
˚C
4
l/min
0.5-10
bar
220-240
V
50
Hz
160
V
170
V
35
mA
6
VA
4060
kΩ