Accessing the Heat Exchanger and Wiring Harness

The heat exchanger and wiring harness are located under the metal cover on the back of the cabinet.
Remove the four (4) screws securing the cover to the back of the cabinet. (Fig. 9 & 10)
Heat
Exchanger
Cover
Screws
Accessing Component in the Freezer Section
The evaporator, automatic ice maker, and other associated components are all accessible inside the
freezer section.
Removing the Automatic Ice Maker
1. Remove the hex-head screw securing the bottom
bracket to the freezer liner.
2. Loosen the two (2) screws in the slotted brackets at
the top of the automatic ice maker three or four
turns.
(These screws must be removed if the
evaporator cover
3. Slide the automatic ice maker up and off the screws.
4. Disconnect the automatic ice maker wiring harness connector and remove the automatic ice
maker from the unit.
5. Remove the extension from the water inlet tube.
Servicing the Evaporator and Other Related Components
The evaporator, evaporator fan, defrost bi-metal and defrost heater are located behind the evaporator
cover.
1. Remove the automatic ice maker, if present. (See procedure above.)
2. Remove the eight (8) screws securing the evaporator cover, ice maker wiring harness cover
and air diffuser in the freezer section. (Fig. 12)
Screws
Fig. 9
is to be removed.) (Fig. 11)
Heat
Exchanger
Wiring
Harness
Fig. 11
10
Fig. 10
LOOSEN
THESE SCREWS
REMOVE
THIS SCREW