9. THERMISTOR & HIGH LIMIT - REAR
• There are two temperature sensing devises located on the Heating Element Assembly Figures 9-1 and 9-2.
• HIGH LIMIT: The High Limit Thermostat (white) is a One-Shot Cut Out (143˚f) Non-resetable.
• THERMISTOR (Rear): The Rear Thermistor (black) cycles the Heating Elements as necessary to maintain temperature. The Rear
Thermister measures inlet air temperature and communicates this information back to the Control Board.
TECH NOTE: The Thermistor has a value of approximately 500k Ohms at room temperature.
9. THERMISTOR - FRONT
• The Front Thermistor is located just behind the Control Panel to the right of the Door Switch (Fig. 9-3). The Front Thermistor
measures exhaust air temperature and communicates this information to the Control Board.
TECH NOTE: The Thermistor has a value of approximately 500k Ohms at room temperature.