Ariston AW 149 NA 수리 매뉴얼 - 페이지 18

{카테고리_이름} Ariston AW 149 NA에 대한 수리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Ariston AW 149 NA 22 페이지. Washer ariston
Ariston AW 149 NA에 대해서도 마찬가지입니다: 사용 및 설치 매뉴얼 (40 페이지), 브로셔 및 사양 (8 페이지)

Ariston AW 149 NA 수리 매뉴얼

13. HEATER

NTC
The Heater is only used in the Sanitize Program (program #1) boosting
the water temperature in that wash cycle to 167º degrees.
The Heater Assembly consists of two components (Fig.13-1).
NTC:
The NTC is used to regulate water temperature.
The NTC can be removed without removing the complete Heater
Assembly but by first loosening the 10mm mounting nut. With the nut
loosened pull the NTC straight out from the Heater Assembly. At room
temperature the NTC has an Ohm of 20k Ohms (Fig. 13-1 & Fig. 13.2).
HEATER ASSEMBLY:
The Heater Assembly can be removed by first removing the 10mm nut
and wiring. Then by using a flat bladed screwdriver carefully pry the
Heater Assembly and Gasket away from the tank housing.
REPAIR MANUAL
WARNING
Fig. 13-1
AW 129 NA / AW 149 NA
NTC
Fig. 13-2
Page: 14