Electrical
connection
: ::: : ah
-:: .: :.: : :: ::; ,: *
Electrical
Shock Hazard
: 2 : Turn power supply
off before
: !
il.-$ connecting
cord.
.:.: :. :
-i:ij.$ Use a new 30 ampere power
.i'l'i ; supp,y cordm
':.!. Plug into a grounded
outlet.
j i ! Failure to follow these
; ; .: instructions
can result in
: : :
: :
death, fire, or electrical
shock.
1
. Turn power supply off.
2
. Remove
hold-down
screw and
terminal
block cover.
external
ground
connecto-
$o$
I terminal
I /
tab
block cover
x
Figure 6
3
. Attach 3/4" U.L.-listed strain relief
(U.L. marking on strain relief) to the
hole below terminal box opening
(set
Figure 7). Tighten strain relief firmly to
cabinet
so it is in a horizontal
position
Place power supply cord through the
strain relief.
rear
strain relief
(outside
power
~o~$lY
dryer)
Figure 7
3
I,
4
. Remove
the center
terminal
block screw. Remove
the neutral
green
with yellow stripe ground
wire from external
ground
conductor
screw. Connect
neutral
green with yellow stripe ground
wire and the neutral wire (white or
center)
of power
supply cord
under the center
screw of terminal
block.
Connect
the other two insulated
wires under outer terminal
block
screws.
Connect
the green, ground
wire
from the power
supply cord to the
external
ground
conductor
screw
(see Figure 8).
Tighten
all terminal
block screws
firmly.
external
ground
connector
green with yellow
stripes (attached
at factory)
/
termi
'/
green
wire from
Figure 8
5
. Tighten
strain relief screws
6
. Insert tab of terminal
block
cover into slot of the dryer rear
panel
(see Figure 6). Secure cover
with hold-down
screw.
.:
,.: :. :: .:: ::
ah
: : : 1
*
Electrical
Shock Hazard
Turn power supply
off before
connecting
wires.
Use 10 gauge solid copper wire.
Electrically
ground
dryer.
Failure to follow these
instructions
can result in death,
fire, or electrical
shock.
. Turn
power supply
off.
ion from the end of
each
insulated
wire (see Figure 9).
tis;onnect
I
I
1 O-gauge,
J-wire with
ground wire
(Romex)
t
red
wire stripped
ot insulation
-5"-
Figure 9
u-shaped hook
P
Shape
the end of each
wire into a 'U" shaped
hook
(see Figure 10). The bare
wire must be 4-l/2"
long
after forming
the hook.
Figure 10
3
. Remove
hold-down
screw and
terminal
block cover.
hold-
down
screw
/
Figure 11
Page 7