Three-wire connection...
DIRECT WIRE OR
POWER SUPPLY CORD
Three-wire power supply cord must
have three, No.-10 copper wires and
match a three-wire receptacle of NEMA
Type 10-30R.
Direct wire power supply cable must be
prepared as shown in "Preparing the
wire" of the three-wire connection
direct-wire steps above.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
10.
To exhaust dryer, see
"Exhaust requirements," Pages 3-4.
Connect exhaust vent to dryer
exhaust outlet and exhaust hood
using 4" (10.2 cm) clamps. Use
caulking to seal exterior wall opening
around exhaust hood.
11.
Carefully move dryer into
final position. Place level on top of
the dryers or collar, first side to side;
then front to back. If the dryer is not
level, adjust the legs of the dryer up
or down until the dryer is level.
12.
Plug power supply cord into
grounded outlet. Or,connect direct
wire to power supply.
Turn power supply on.
Where local codes Do Not permit
connecting cabinet-ground conductor to neutral wire:
4.
Remove center terminal block
screw.
5.
Remove the appliance harness
ground wire (green with yellow
stripes) from the external ground
connector screw. Connect
appliance harness ground wire and
the neutral wire (white or center) of
the power supply cord/cable under
the center, silver-colored terminal
block screw. Tighten screw.
6.
Connect the other wires to outer
terminal block screws. Tighten
screws.
7.
Tighten strain relief screws.
8.
Insert tab of terminal block cover
into slot of dryer rear panel. Secure
cover with hold-down screw.
13.
Check dryer operation (some
accumulated time may be on the
timer due to factory testing).
Insert coins in slide and press slide in
slowly. (Operating time will
accumulate per number of coins and
type of timing cam used.) Push
START/RESTART button. Using a full
heat cycle (not the air cycle), let the
dryer run for at least five minutes.
Dryer will stop when time is used up.
Note: Dryer door must be closed for
dryer to operate. When door is open,
dryer stops, but timer continues to run.
To restart dryer, close door and push
START/RESTART button.
14.
If drying time is too long,
make sure lint screen is clean.
Three-wire receptacle
9.
After reattaching the terminal
cover, connect a separate copper
ground wire from the external
ground connector screw to an
adequate ground.
15.
it to complete a full heat cycle (not
air cycle) to make sure it is working
properly.
Now start the dryer and allow
Page 11