Whirlpool 8528095 REV A 설치 지침 매뉴얼 - 페이지 4

{카테고리_이름} Whirlpool 8528095 REV A에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool 8528095 REV A 28 페이지. Electric dryer

Whirlpool 8528095 REV A 설치 지침 매뉴얼
Product Dimensions
Dimensions shown with feet extended 2.5 cm (1") from
bottom of dryer.
27.9 cm
(11")
109.5 cm
(43-1/8")
97.2 cm
(38-1/4")
74.3 cm
(29-1/4")
Exhaust dimensions
35.9 cm
(14-1/8")
back
exhaust
4
terminal block cover
power supply
cord/cable
strain relief
The dryer door
extends 35.6 cm (14")
from the front of the
dryer when fully
opened.
68.6 cm (27")
10.2 cm
(4")
26 cm
(10-1/4")
left or right
side exhaust
Important: Observe all governing codes and ordinances.
This dryer is supplied/fitted with an electricity supply cord and
European 16A plug. It should be connected to electricity supply
socket at the voltage shown on the rating plate. The minimum
supply fuse capacity should be 16A. The dryer must be
positioned so that the plug is accessible. If the fitted plug is not
used, the electrical connection must be carried out by a
competent electrician in accordance with local or national codes.
If the supply cord is damaged, it must be replaced with a
specially terminated cord by an authorized service agent or a
35.6
similarly competent person.
cm
Do not use an adapter.
(14")
Do not use an extension cord.
Electrical earthing is required on this dryer.
Do not earth to a gas pipe.
Do not change the power supply cord plug. If it does
not fit the outlet, have a proper outlet installed by a
qualified electrician.
Do not have a fuse in the neutral or earthing circuit.
Do not use an extension cord with this dryer.
Check with a qualified electrician to be sure the dryer is
properly earthed.
Do not connect plug end of power supply cord into a
live receptacle before connecting power supply cord to
dryer terminal block.
Do not reuse old power supply cord.
Failure to follow these instructions could result in
death, fire, or serious injury.
10.8 cm
(4-1/4")
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond, path is adequate.

Electrical Requirements

WARNING
Electrical Shock Hazard