4. Install the two hinges to the front panel of the dryer using
4 screws. Use the non-slotted side to attach the hinge
to the front panel.
5. Install screws in top hinge holes in the door. Do not tighten
screws. Leave approximately 1/4" (5 mm) of screw exposed
6. Hang door by placing screw heads into top slotted holes of
hinges and slide door down. Align bottom screw holes in hinge
and door. Install two bottom screws. Tighten all hinge screws.
7. Close door to engage door strike.
16
TROUBLESHOOTING
DRYER OPERATION
Dryer will not run
.
Has a household fuse blown, or has a circuit breaker
■
tripped?
There may be two household fuses or circuit breakers
for the dryer. Check that both fuses are intact and tight,
or that both circuit breakers have not tripped. Replace
the fuse or reset the circuit breaker. If the problem
continues, call an electrician.
Is the correct power supply available?
■
Electric dryers require a 240-volt power supply. Check
with a qualified electrician.
Was a regular fuse used?
■
Use a time-delay fuse.
No heat
Has a household fuse blown, or has a circuit breaker
■
tripped?
The drum may be turning, but you may not have heat.
Elelctric dryers use two household fuses or circuit breakers.
Replace the fuse or reset the circuit breaker. If the problem
continues, call an electrician.
Dryer displaying code message
"PF" (power failure), check the following:
■
Was the drying cycle interrupted by a power failure?
Press and hold START/PAUSE to restart the dryer.
Try the following:
Check to see if a household fuse has blown or circuit breaker
has tripped. Electric dryers use two household fuses or
breakers. Replace the fuse or reset the circuit breaker.
Confirm the power cord is properly installed.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualified electrician.
"F" Variable (F1E1, F2E2, F3E1, F3E2, F7E1, F3E6, F3E7)
■
service codes:
Call for service.