Whirlpool CGM2761TQ0 설치 지침 매뉴얼 - 페이지 16
{카테고리_이름} Whirlpool CGM2761TQ0에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool CGM2761TQ0 36 페이지. Commercial gas or electric dryer
CHANGING TO A 30- OR
SO-MINUTE TIMINGCAM
Emectricat Shock Hazard
Disconnect
power before making cam changes.
Failure to follow
these }nstructions
can resumt }n death
or electrical
shock.
You can install the 30-minute or 60-minute timing cam (shipped
with dryer) as follows:
1, Unplug dryer or disconnect power.
2, Unlock meter case.
3, Turn the timing cam by hand until the V-shaped notch lines up
below the ratchet tooth.
B. Timing cam
C. Drive lug
D. V-shaped notch
4, Insert a narrow, fiat-blade screwdriver under the timing cam
near the clock shaft. Gently Iift cam straight up and off shaft
making sure that the V-shaped notch clears the ratchet tooth.
5, Place new cam (hub side down) over clock shaft. Line up fiat
side of shaft with fiat side of cam hole. Check that drive Iug is
in place.
6, Turn cam until V-shaped notch lines up with ratchet tooth.
7, Press cam down in place on motor shaft. Make sure that
',i-shaped notch ciears the ratchet tooth.
8, Close and lock the meter case.
16