Whirlpool CGM2793BQ 설치 지침 매뉴얼 - 페이지 14
{카테고리_이름} Whirlpool CGM2793BQ에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool CGM2793BQ 48 페이지. Commercial dryer gas or electric
Whirlpool CGM2793BQ에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (48 페이지)
DRYER VENTING
REQUIREMENTS
Vent Hoods
4" (102 ram} Diameter
Exhaust Hoods
Box Hood
Louvered Hood
Angled Hood
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, bushes, or snow).
Vent System
Length
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
3. Tighten hose clamp with Phillips screwdriver.
Vent System Chart (Rigid Metal Vent}
No. of
Box and
Angled
90 ° Turns
Louvered Hood
Hood
0
64 ft. (19.5 m)
58 ft. (17.7 m)
1
54 ft. (16.5 m}
48 ft. (14.6 m}
2
44 ft. (13.4 m)
38 ft. (11.6 m)
3
35 ft. (10.7 m)
29 ft. (8.8 m}
4
27 ft. (8.2 m}
21 ft. (8.4 m}
For vent systems not covered by the vent specification
chart,
see your parts distributor.
Provision must be made for enough air for combustion
and
ventilation. (Check governing codes and ordinances.) See
"Recessed Area and Closet Installation Instructions"
in the
"Location Requirements"
sections.
A 4" (102 mm) outlet hood is preferred. However, a 21/2 ''
(64 mm) outlet exhaust hood may be used. A 21/2"(64 mm)
outlet creates greater back pressure than other hood types.
For permanent installation, a stationary vent system is required.
Connect
Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer.
Vent Collar
4. Make sure the vent is secured to exhaust hood with
a 4" (102 mm) clamp.
5. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.
NOTE: Do not remove vent collar.
14