Whirlpool CGM2793BQ 설치 지침 매뉴얼 - 페이지 9

{카테고리_이름} Whirlpool CGM2793BQ에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool CGM2793BQ 48 페이지. Commercial dryer gas or electric
Whirlpool CGM2793BQ에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (48 페이지)

Whirlpool CGM2793BQ 설치 지침 매뉴얼
GAS DRYER INSTALLATION REQUIREMENTS
Gas Supply
Explosion Hazard
Use a new CSA International approved
gas supply line.
Install a shut=off valve,
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service personnel.
Failure to do so can result in death, explosion,
or fire.
IMPORTANT:
Observe all governing codes and ordinances.
This installation must conform with all local codes and
ordinances.
In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54 or CAN/CSA B149.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Battewmarch
Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this dwer has been certified by CSA International
for use at altitudes up to 10,000 feet (3048 m) above sea level
at the B.T.U. rating indicated on the model/serial
plate. Burner
input adjustments
are not required when the dwer is operated
up to this elevation.
When installed above 10,000 feet (3048 m), a four percent
(4%) reduction of the burner B.T.U. rating shown on the model/
serial plate is required for each 1,000 foot (305 m) increase in
elevation. For assistance when converting to other gas types
and/or installing above 10,000 feet (3048 m) elevation, contact
your local service company.
9