ExpJosion Hazard
Use a new AGA or CSA approved
gas supply tine.
Install a shut-off
vaJve.
SecureJy tighten all gas connections.
ff connected
to LP, have a qualified
person make
sure gas pressure
does not exceed 13" (33 cm)
water column.
Examples
of a qualified
person inctude:
ticensed
heating
personneJ,
authorized
gas company
personnel,
and
authorized
service personnel.
Failure to do so can result in death, explosion,
or fire.
Gas Type
Natural gas:
This dryer is equipped for use with NATURAL GAS. It is design-
certified by CSA International for L.R (propane or butane) gases
with appropriate
conversion.
•
Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate
in the door well of your dryer. If this information
does not
agree with the type of gas available, contact your dealer or
call the phone numbers referenced in the "Assistance
or
Service" section of this manual.
L.P. gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
Gas supply
line
•
1/2in. IPS pipe is recommended.
•
3/8in. approved tubing is acceptable for lengths under 20 ft
(6.1 m) if local codes and gas supplier permit.
•
Must include v8in. NPT plugged tapping accessible for test
gage connection,
immediately upstream of the gas
connection to the dryer (see following illustration).
•
Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within six
(6) feet (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shutoff valve must be installed in
accordance
with the B149, Natural Gas and Propane
Installation Code. It is recommended
that an individual
manual shutoff valve be installed within six (6) feet (1.8 m) of
the dryer.
The location should be easy to reach for opening and closing.
3
5
2
4
1. % in. flexible gas connector
2. ¾ in. pipe to flare adapter fitting
3. V8in. NPT plugged tapping
4. Y2in. NPT gas supply line
5. Gas shutoff valve
Gas supply connection requirements
There are many methods by which your gas dryer can be
connected to the gas supply. Listed here are some guidelines for
two different methods of connection.
Option
1 (Recommended
method)
Flexible stainless steel gas connector:
•
If local codes permit, use a new flexible stainless steel gas
connector (Design Certified by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8in. flare x 8/8in. NPT
adapter fitting between the stainless steel gas connector and
the dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate
method)
Approved aluminum or copper tubing:
•
Lengths under 20 ft (6.1 m) can use 8/8in. approved tubing (if
codes and gas supplier permit).
•
If you are using natural gas, do not use copper tubing.
•
% in. flare x % in. NPT adapter fitting between dryer pipe and
% in. approved tubing.
•
Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.
•
If your dryer has been converted to use L.R gas, % in. L.R
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft (6.1 m), use larger tubing.
NOTE: Pipe joint compounds
that resist the action of L.R gas
must be used. Do not use TEFLON _r tape.
Dryer gas pipe
•
The gas pipe that comes out through the rear of your dryer
has a % in. male pipe thread.
*61/4"
,2
(!5.88
cm)
.....
.......
11 2
1
(3,8t cm)
1. Y2in. NPT gas supply line
2. _in.
NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 13 in. (33 cm) from the floor.
t®TEFLON is a registered trademark