Dryerdisplaying codemessage
•
"PF" (power failure), check the following:
Was the drying cycle interrupted
by a power failure?
Press and hold START to restart the dryer.
"F-" Variable (F-01, F-22, F-23, F-26) service codes (the
display alternately flashes
"F-" and then the error code
number):
Call for service.
Clothes are not drying satisfactorily, drying times are too
long, or load is too hot
•
Is the lint screen clogged with lint?
Lint screen should be cleaned before each load.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow
these instructions can result in death
or fire.
Is the exhaust vent or outside exhaust hood clogged with
lint, restricting air movement?
Run the dryer for 5-10 minutes. Hold your hand under the
outside exhaust hood to check air movement.
If you do not
feel air movement, clean exhaust system of lint or replace
exhaust vent with heavy metal or flexible metal vent. See
"Venting Requirements."
Are fabric softener sheets blocking the grille?
Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length?
Check that the exhaust vent is not too long or has too many
turns. Long venting will increase drying times. See "Plan Vent
System."
Is the exhaust vent diameter the correct
size?
Use 4" (10.2 cm) diameter vent material.
Explosion
Hazard
Keep flammable
materials
and vapors, such as
gasoline,
away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
•
Is the dryer located
in a room with temperature
below
45°F (7°0)?
Proper operation of dryer cycles requires temperatures
above
45°F (7°C).
•
Is the dryer located in a closet?
Closet doors must have ventilation openings at the top and
bottom of the door. The front of the dryer requires a minimum
of 1" (2.5 cm) of airspace, and, for most installations, the rear
of the dryer requires 5" (12.7 cm). See "Installation
Instructions."
•
Has the Air Only temperature
setting
been selected?
Select the right temperature for the types of garments being
dried. See "Additional Features."
•
Is the load too large and heavy to dry quickly?
Separate the load to tumble freely.
Cycle time too short
Excessive
Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
•
Is the automatic
cycle ending early?
The load may not be contacting the sensor strips. Level the
dryer.
Change the dryness level setting on Auto Cycles. Increasing
or decreasing the dryness level will change the amount of
drying time in a cycle.
Do not use a dryer rack with an Auto Cycle.
21