Whirlpool XCGM2765 설치 지침 매뉴얼 - 페이지 15
{카테고리_이름} Whirlpool XCGM2765에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool XCGM2765 23 페이지. Commercial gas or electric dryer
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
In Australia and New Zealand, refer to AS/NZS 5601.1 – Gas
Installations.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
102 mm (4") Heavy, Metal Exhaust Vent
Only a 102 mm (4") heavy, metal exhaust vent and clamps
■
may be used.
Do not use plastic or metal foil vent.
■
Rigid metal vent:
Recommended for best drying performance and to avoid
■
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in final dryer location.
■
Remove excess to avoid sagging and kinking that may result
■
in reduced airflow and poor performance.
Do not install in enclosed walls, ceilings, or floors.
■
The total length should not exceed 2.4 m (7
■
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or flexible metal vents. Review "Vent System Chart" and,
if necessary, modify existing vent system to achieve best drying
performance.
DRYER VENTING REQUIREMENTS
102 mm
(4")
⁄
ft.).
3
4
Elbows:
45° elbows provide better airflow than 90° elbows.
■
Good
Clamps:
Use clamps to seal all joints.
■
Exhaust vent must not be connected or secured with screws
■
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Better
15