Model number: FP522V
Thank you for purchasing our smoke alarm device. Please
take a few minutes to read the user's manual thoroughly and
familiarise yourself and your family with its operation. And
save it for future reference.
Diagram 1
Product Specifi cations:
• POWER: built-in DC3V(CR123A) Lithium battery
(battery not replaceable)
• OPERATION CURRENT: <8uA (standby), <70mA
(alarm)
• ALARM VOLUME: >85dB(A) at 3 meters.
• ALARM SENSITIVITY: 0.115-0.181dB/m
• SILENCE TIME: approx. 10 minutes
• SMOKE ALARM DEVICE SOUND PATTERN:
ISO8201(BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s –
BI 0.5s – pause 1.5s, with the red LED fl ash, repeat this
alarm pattern).
• COMPLY WITH STANDARD: AS3786:2014
Description:
The unit is a photoelectric smoke alarm device. The
photoelectric technology is more sensitive to detecting slow
smoulder fi res which, in general, have thick, black smoke,
a little heat and may smoulder for hours before bursting
into fl ames. The smoke alarm device does not contain any
material which is harmful to the environment.
The smoke alarm device should be installed in every room
(except bathrooms and kitchens), and all other living areas,
to ensure the alarm can be heard from anywhere in the home
and you can respond accordingly. For minimum protection,
you should fi t an alarm in all hallways, living rooms,
bedrooms and child rooms, placing each unit in the middle
of the ceiling of each room for maximum protection.
Ref: ST522E
Recommended installation in a typical single storey
dwelling:
Install a smoke alarm device on the ceiling inside each
bedroom and in the hallway outside each separate sleeping
area. If a bedroom area hallway is more than 10m long,
install a smoke alarm device at each end. If there is a
basement: install a smoke alarm device on the basement
ceiling at the bottom of the stairwell.
Recommended installation in a typical multi-storey
dwelling:
Install a smoke alarm device on the ceiling inside each
bedroom and in the hallway outside each separate sleeping
area. If a bedroom area hallway is more than 10m long,
install a smoke alarm device at each end install a smoke
alarm device at the top of a fi rst – to- second fl oor stairwell.
Important Safety Information:
1: The test button accurately tests smoke alarm device
2: If you're sure it isn't a fi re, open windows or fan the air
3: Observe and follow all local and national electrical and
4: This smoke alarm device is designed to be used inside
5: Install a smoke alarm device in every room and on every
6: Smoke alarm device may not alert every household
- 1 -
functions. Do not use any other test method. Test smoke
alarm device weekly to ensure proper operation.
around smoke alarm device to silence it
building codes for installation.
a single family only. In multifamily buildings, each
individual living unit should have its own smoke alarm
devices. Do not install in non-residential buildings. This
smoke alarm device is not a substitute for a complete
alarm system.
level of the home. Smoke may not reach the smoke alarm
device for many reasons. For example, if a fi re starts in a
remote part of the home, on another level, in a chimney,
wall, roof, or on the other side of a closed door, smoke
may not reach the smoke alarm device in time to alert
household members. A smoke alarm device will not
promptly detect a fi re except in the area or room in which
it is installed.
member every time. The alarm horn is loud in order
to alert individuals to a potential danger. However,
there may be some circumstances where a household
member may not hear the alarm (i.e. outdoor or indoor
noise, sound sleepers, drug or alcohol usage, the hard of
hearing, etc.). If you suspect that this smoke alarm device
may not alert a household member, install and maintain
specialty smoke alarm devices. Household members must
beable to hear the alarm's warning sound and quickly
Document NO.: FP522V-001 2020.02.18 Version: A