Whirlpool (91.) ISLAND-MOUNT CANOPYRANGE 사용 및 관리 매뉴얼 - 페이지 4
{카테고리_이름} Whirlpool (91.) ISLAND-MOUNT CANOPYRANGE에 대한 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool (91.) ISLAND-MOUNT CANOPYRANGE 32 페이지. 36" (91.4 cm) island-mount canopy range hood
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools needed
Level
Drill with 1¼" (3.0 cm), ³⁄₈" (9.5 mm), ⁷⁄₆₄" (2.75 mm) and
¹⁄₈" (3.0 mm) drill bits
Pilot hole drill bits (determined by chimney support
attachment method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts needed
Home power supply cable
½" (12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also
need:
Recirculating Kit Part Number W10294734 for non-vented
(recirculating) installations only. See "Assistance or Service"
section to order.
6" (15.2 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood ventilator assembly with canopy glass, retainer
brackets, rubber seals, and LED lights installed.
Metal grease filter
60 - 4.2 x 8 mm screws
4 - 3.5 x 6.5 mm screws
2 - 2.9 x 3 mm screws
4 - 5 x 45 mm screws
®†
T10 Torx
adapter
T20
®†
Torx
®
adapter
2 - Upper vent covers
2 - Lower vent covers
4 - Plastic vent clips
Mounting template
Upper horizontal support bracket
Horizontal support
8 - Vertical supports
Vent transition with back draft damper installed.
2 - 3.5 x 9.5 mm mounting screws
†®TORX and T20 are registered trademarks of Acument Intellectual Properties, Inc.
4
INSTALLATION REQUIREMENTS
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located
behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 lbs (36.6 kg).
This range hood is recommended for use with cooktops with a
maximum total rating of 60,000 BTUs or less.
The range hood is factory set for venting through the roof or wall.
For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installation" in "Install Range Hood" section.
Recirculating Kit Part Number W10294734 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
A
F
A. 12¼" (31.1 cm)
³⁄₁₆
B. 13
" (33.5 cm)
³⁄₄
C. *29
" (75.6 cm) min.
¹³⁄₁₆
44
" (113.8 cm) max.
³⁄₄
**29
" (75.6 cm) min.
¹³⁄₁₆
49
" (126.5 cm) max.
*Vented installations only
**Non-vented (recirculating) installations only
B
C
D
E
¹⁄₂
D. 3
" (8.9 cm)
E. 36" (91.4 cm)
³⁄₁₆
F. 25
" (64.0 cm)