Whirlpool AKR912CIXM 사용 설명서 - 페이지 9

{카테고리_이름} Whirlpool AKR912CIXM에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool AKR912CIXM 14 페이지. Whirlpool t- box hood instruction manual

Whirlpool AKR912CIXM 사용 설명서
1. Attach an adequate length of
area of the air outlet adapter.
2. The duct has to be secured using two screws from two sides of the air
outlet adapter. Make sure the duct is fixed well on.
DESCRIPTION/CONNECTIONS
Ducted mode air exhaust system
The hood draws the cooking fumes saturated with fumes and odor through
the grease filters and expels it to the outside through an outlet pipe.
Caution: To reduce the risk of fire, use metal
ductwork only.
1. Decide where the ductwork will run
between the hood and the outside.
2. A straight, short duct run will allow the
hood to perform most efficiently.
3. Long duct runs, elbows, and transitions
will reduce the performance of the hood.
Use as few of them as possible. Larger
ducting
may
performance with longer duct runs.
4. Attach an adequate length of
adapter. Let the exhaust run for a minimum of 1 meter in Straight line in
between bends / elbows for better efficiency.
5. The air must not be discharge into a flue that is used for exhausting
fumes from appliances burning gas or other fuels" "Regulations
concerning the discharge of air have to be fulfilled.
φ
150mm round duct into the recessed
be
required
for
φ
8
best
160mm round duct to the air outlet